Show simple item record

dc.contributor.authorBruvoll, Ragnar Bjørn Watte
dc.contributor.authorBlakkisrud, Johan
dc.contributor.authorMikalsen, Lars Tore Gyland
dc.contributor.authorConnelly, James Pattrick
dc.contributor.authorStokke, Caroline
dc.date.accessioned2024-02-22T07:23:36Z
dc.date.available2024-02-22T07:23:36Z
dc.date.created2023-06-16T09:18:50Z
dc.date.issued2023
dc.identifier.issn2072-6694
dc.identifier.urihttps://hdl.handle.net/11250/3119140
dc.description.abstractPurpose: The aim of this paper was to investigate correlations between pre- therapeutic [68Ga]Ga-DOTA-TOC uptake and absorbed dose to tumours from therapy with [177Lu]Lu-DOTA- TATE. Methods: This retrospective study included 301 tumours from 54 GEP-NET patients. The tumours were segmented on pre-therapeutic [68Ga]Ga-DOTA-TOC PET/CT, and post-therapy [177Lu]Lu-DOTA-TATE SPECT/CT images, using a fixed 40% threshold. The SPECT/CT images were used for absorbed dose calculations by assuming a linear build-up from time zero to day one, and mono-exponential wash-out after that. Both SUVmean and SUVmax were measured from the PET images. A linear absorbed-dose prediction model was formed with SUVmean as the inde- pendent variable, and the accuracy was tested with a split 70–30 training-test set. Results: Mean SUVmean and SUVmax from [68Ga]Ga-DOTA-TOC PET was 24.0 (3.6–84.4) and 41.0 (6.7–146.5), and the mean absorbed dose from [177Lu]Lu-DOTA-TATE was 26.9 Gy (2.4–101.9). A linear relationship between SUVmean and [177Lu]Lu-DOTA-TATE activity concentration at 24 h post injection was found (R2 = 0.44, p < 0.05). In the prediction model, a root mean squared error and a mean absolute error of 1.77 and 1.33 Gy/GBq, respectively, were found for the test set. Conclusions: There was a high inter- and intra-patient variability in tumour measurements, both for [68Ga]Ga-DOTA-TOC SUVs and absorbed doses from [177Lu]Lu-DOTA-TATE. Depending on the required accuracy, [68Ga]Ga- DOTA-TOC PET imaging may estimate the [177Lu]Lu-DOTA-TATE uptake. However, there could be a high variance between predicted and actual absorbed doses.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleCorrelations between 68Ga]Ga-DOTA-TOC Uptake and Absorbed Dose from [177Lu]Lu-DOTA-TATEen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.3390/cancers15041134
dc.identifier.cristin2155141
dc.source.journalCancersen_US
dc.source.volume15en_US
dc.source.issue4en_US