Vis enkel innførsel

dc.contributor.authorSevaldsen, Kirsti
dc.contributor.authorHusby, Otto Schnell
dc.contributor.authorLian, Øystein Bjerkestrand
dc.contributor.authorHusby, Vigdis Schnell
dc.date.accessioned2021-09-23T09:27:22Z
dc.date.available2021-09-23T09:27:22Z
dc.date.created2020-06-10T14:55:09Z
dc.date.issued2020-06-18
dc.identifier.citationHIP International. 2020, 1-6.en_US
dc.identifier.issn1120-7000
dc.identifier.issn1724-6067
dc.identifier.urihttps://hdl.handle.net/11250/2780723
dc.description.abstractBackground: The line-to-line cementing technique is proposed to create a press-fit in the femoral canal, which is contrary to modern cementing techniques. The term ‘French paradox’ has been used to describe the acceptable results associated with this technique. It has been suggested that the quality of the mantle may not be satisfactory, predisposing to early failure and aseptic loosening. Methods: The line-to-line cementing technique, where the femoral stem was oversized by 1 size compared to the broach, was compared to the standard cementing technique using corresponding sized broaches and stems, in 6 pairs of human cadaver femora with taper-slip design C-stems. Cement pressure was measured, and cement mantle thickness was analysed. A mixed effects model with random intercepts was used to examine the relationship between thickness of mantle and cementing technique and between pressure and cementing technique. Results: Line-to-line cementing results in significantly higher pressurisation for longer periods of time leading to better interdigitation but a thinner mantle in some areas. Conclusions: The results of this study describe the in-vitro advantages and disadvantages of the line-to-line cementing technique.en_US
dc.description.sponsorshipThe Liaison Committee for Education, Research and Innovation in Central Norway, Norwegian University of Science and Technology (Grant number 46055500-6) and Research Department, Møre og Romsdal HF Health Trust.en_US
dc.language.isoengen_US
dc.publisherSAGE Publicationsen_US
dc.relation.ispartofseriesHIP International;
dc.relation.urihttps://journals.sagepub.com/doi/10.1177/1120700020934368
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectFrench Paradoxen_US
dc.subjectHip Arthroplastyen_US
dc.subjectBone cementen_US
dc.subjectCementing techniquesen_US
dc.titleDoes the line-to-line cementing technique of the femoral stem create an adequate cement mantle?en_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© The Author(s) 2020en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doihttps://doi.org/10.1177/1120700020934368
dc.identifier.cristin1814852
dc.source.journalHIP Internationalen_US
dc.source.pagenumber1-6en_US
dc.relation.projectSamarbeidsorganet mellom Helse Midt-Norge og NTNU: 46055500-6en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal