Show simple item record

dc.contributor.authorLiu, Jiying
dc.contributor.authorSun, Mengtao
dc.contributor.authorKim, Moon Keun
dc.contributor.authorSong, Shoujie
dc.date.accessioned2023-11-03T07:31:54Z
dc.date.available2023-11-03T07:31:54Z
dc.date.created2023-08-23T08:44:04Z
dc.date.issued2023
dc.identifier.citationJournal of Asian Architecture and Building Engineering. 2023, 1-19.en_US
dc.identifier.issn1346-7581
dc.identifier.urihttps://hdl.handle.net/11250/3100383
dc.description.abstractTo upgrade the computational efficiency and ensure the accuracy of calculated cooling capacity of radiant cooling floor, this study proposed a simplified three-dimensional modeling by combining with a user-defined function compilation. The cooling capacity and minimum floor temperature were taken as evaluation indices considering different radiant floor thick- nesses, layers’ thermal conductivities, pipe diameters, pipe spacing, and floor surface sizes. Moreover, a backpropagation neural network model and a prediction program were developed to quickly predict minimum floor temperature and cooling capacity. The results demonstrate that the established backpropagation neural network model can predict the values of cooling capacity and minimum floor temperature well, and the coefficients of determination were 0.9117 and 0.9435, respectively. With the thickness increase of cover layer and filling layer, the minimum floor temperature respectively increases by 10.97% and 11.01%. With the heat transfer coefficient increase of cover layer and filling layer, cooling capacity respectively increases by 30.56% and 23.46%. This study proposes an artificial intelligence method for the rapid prediction of cooling capacity and minimum floor temperature, and provides their theoretical support for engineering application.en_US
dc.language.isoengen_US
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleDeveloping simplified numerical calculation and BP neural network modeling for the cooling capacity in a radiant floor cooling systemen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1080/13467581.2023.2244730
dc.identifier.cristin2168879
dc.source.journalJournal of Asian Architecture and Building Engineeringen_US
dc.source.pagenumber1-19en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse-Ikkekommersiell 4.0 Internasjonal