dc.identifier.citationJournal of Building Engineering. 2022, 54 1-20.en_US
dc.identifier.issn2352-7102
dc.identifier.urihttps://hdl.handle.net/11250/3064519
dc.description.abstractThe development of collaborative control strategies for radiant cooling and ventilation systems improves thermal comfort and energy efficiency. This study used the Transient System Simulation (TRNSYS) tool integrated with the parametric simulation manager jEPlus to determine the optimal starting and operation mode of a combined radiant floor cooling (RFC) and ventilation system. The results were validated by an experiment. The optimization process was constrained by the thermal comfort defined by the predicted mean vote (PMV) with the objective of minimizing energy consumption. The results showed that the ventilation system was started 1 h earlier than the RFC system at an initial indoor humidity of 85% to prevent condensation, whereas both systems were started at the same time at 75% in the starting stage. In the operation stage, the self-regulation potential of the RFC system and the adjustment of the cooling capacity of the ventilation system were coordinated to counter dynamic internal heat gains. Moreover, the proportion of the total sensible heat removed by the RFC system to the total sensible heat removed by the ventilation system (Sv/SR) was positively correlated with the total energy consumption. The Sv/SR must be sufficiently high to prevent a large PMV deviation from the comfort zone of −0.5 to 0.5. A collaborative control strategy using the PMV-based model was proposed to adjust the Sv/SR according to the PMV range, resulting in a highly efficient operation and maximum energy savings of 26.2%.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.ispartofseriesJournal of Building Engineering;
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleDeveloping a collaborative control strategy of a combined radiant floor cooling and ventilation system: A PMV-based modelen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionacceptedVersionen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.fulltextpostprint
cristin.qualitycode1
dc.identifier.doihttps://doi.org/10.1016/j.jobe.2022.104648
dc.identifier.cristin2033545
dc.source.journalJournal of Building Engineeringen_US
dc.source.volume54en_US
dc.source.pagenumber1-20en_US