Vis enkel innførsel

dc.contributor.authorMadjlessi, Noosha
dc.contributor.authorCotsovos, Demitrios M.
dc.contributor.authorMoatamedi, Mojtaba
dc.date.accessioned2022-03-28T14:11:55Z
dc.date.available2022-03-28T14:11:55Z
dc.date.created2022-01-25T13:08:17Z
dc.date.issued2021-05-05
dc.identifier.citationStructural Concrete. 2021, 22 (4), 2070-2088.en_US
dc.identifier.issn1464-4177
dc.identifier.issn1751-7648
dc.identifier.urihttps://hdl.handle.net/11250/2988108
dc.description.abstractThe work presented herein sets out to investigate experimentally, via drop-weight testing, the behavior of slender reinforced concrete (RC) beam specimens under impact loading. During testing, the behavior of each specimen is established through the combined use of conventional instrumentation and a high-speed video camera. The primary objective of this work is to investigate the reasons that trigger the observed shift in specimen behavior (compared to that established from static tests) with increasing levels of applied loading rate and intensity. Analysis of the test data reveals that during drop-weight testing only a portion of the element span reacts to the applied load (as indicated by the deformation and cracking profiles recorded) which in turn affects the mechanics underlying specimen behavior and therefore, significantly influencing the mode of failure ultimately exhibited. The observed localized response becomes more prominent by increasing the loading rate and intensity of the imposed impact loading. In addition to the above, the strain-rate sensitivity of the material properties of concrete does not appear to have a significant effect on the behavior of the specimens tested. The aforementioned observations appear to be in conflict with current design practice raising questions concerning the effectives of the design solutions produced.en_US
dc.language.isoengen_US
dc.publisherWiley-VCH Verlagen_US
dc.relation.ispartofseriesStructural Concrete;Volume 22, Issue 4
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectCrackingen_US
dc.subjectDrop-weight testingen_US
dc.subjectDynamic responsesen_US
dc.subjectImpactsen_US
dc.subjectReinforced concreteen_US
dc.subjectSlender beamsen_US
dc.titleDrop-weight testing of slender reinforced concrete beamsen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2021 The Authorsen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doihttps://doi.org/10.1002/suco.202000395
dc.identifier.cristin1989489
dc.source.journalStructural Concreteen_US
dc.source.volume22en_US
dc.source.issue4en_US
dc.source.pagenumber2070-2088en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal