dc.identifier.citationMussmann, Mørup, Marschall-Skov, Foley, Brenøe, Precht. Organ-based tube current modulation in chest CT. A comparison of three vendors. Radiography. 2020en
dc.identifier.issn1078-8174
dc.identifier.issn1532-2831
dc.identifier.urihttps://hdl.handle.net/10642/9536
dc.description.abstractIntroduction: Organ-based tube current modulation (OBTCM) is designed for anterior dose reduction in Computed Tomography (CT). The purpose was to assess dose reduction capability in chest CT using three organ dose modulation systems at different kVp settings. Furthermore, noise, diagnostic image quality and tumour detection was assessed. Methods: A Lungman phantom was scanned with and without OBTCM at 80e135/140 kVp using three CT scanners; Canon Aquillion Prime, GE Revolution CT and Siemens Somatom Flash. Thermo-luminescent dosimeters were attached to the phantom surface and all scans were repeated five times. Image noise was measured in three ROIs at the level of the carina. Three observers visually scored the images using a fivestep scale. A Wilcoxon Signed-Rank test was used for statistical analysis of differences. Results: Using the GE revolution CT scanner, dose reductions between 1.10 mSv (12%) and 1.56 mSv (24%) (p < 0.01) were found in the anterior segment and no differences posteriorly and laterally. Total dose reductions between 0.64 (8%) and 0.91 mSv (13%) were found across kVp levels (p < 0.00001). Maximum noise increase with OBTCM was 0.8 HU. With the Canon system, anterior dose reductions of 6e10% and total dose reduction of 0.74e0.76 mSv across kVp levels (p < 0.001) were found with a maximum noise increase of 1.1 HU. For the Siemens system, dose increased by 22e51% anteriorly; except at 100 kVp where no dose difference was found. Noise decreased by 1 to 1.5 HU. Conclusion: Organ based tube current modulation is capable of anterior and total dose reduction with minimal loss of image quality in vendors that do not increase posterior dose. Implications for practice: This research highlights the importance of being familiar with dose reduction technologies.en
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesRadiography;Volume 27, Issue 1
dc.subjectChestsen
dc.subjectComputed tomographyen
dc.subjectRadiation dosesen
dc.subjectImage qualitiesen
dc.titleOrgan-based tube current modulation in chest CT. A comparison of three vendorsen
dc.typeJournal articleen
dc.typePeer revieweden
dc.date.updated2020-11-18T08:47:50Z
dc.description.versionpublishedVersionen
dc.identifier.doihttps://doi.org/10.1016/j.radi.2020.04.011
dc.identifier.cristin1849079
dc.source.journalRadiography


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record