Vis enkel innførsel

dc.contributor.authorCablé, Axel
dc.contributor.authorHammer, Hugo Lewi
dc.contributor.authorMysen, Mads
dc.date.accessioned2016-07-25T06:45:52Z
dc.date.accessioned2017-04-05T13:58:27Z
dc.date.available2016-07-25T06:45:52Z
dc.date.available2017-04-05T13:58:27Z
dc.date.issued2016-03-29
dc.identifier.citationThe International Journal of Ventilation 2016, 14(4):371-382language
dc.identifier.issn2044-4044
dc.identifier.urihttps://hdl.handle.net/10642/4683
dc.description.abstractThe perceived indoor climate resulting from two ventilation control strategies was evaluated in a classroom of the first school built according to the Norwegian passive house standard. Both strategies consisted of varying the ventilation rate according to room demand, ie. Demand-Controlled Ventilation (DCV). The existing strategy consisted of varying the ventilation rate in order to maintain a constant carbon dioxide concentration of 800 ppm in the classroom (constant-CO2 control). A new strategy was implemented which consisted of a combined CO2 and temperature control, ie. to control towards a proportionally lower CO2 concentration when the indoor temperature increases. The aim with this strategy was both to address overheating and the fact that perceived indoor air quality decreases when temperature rises. Indoor climate measurements, as well as questionnaires on the perceived indoor air quality and thermal comfort (completed by the pupils), were used to compare both strategies. An acceptable perceived indoor climate was reported for both strategies, with a slight improvement for the combined CO2 and temperature control. The data from the questionnaires were then analyzed using a random effect linear regression model. The regression analysis revealed that the combined CO2 and temperature control reduced the discomfort by variations of the indoor temperature significantly compared to the existing strategy (constant-CO2 control). If correctly implemented, combined CO2 and temperature DCV therefore appears to be a relevant solution for schools built to passive house standard.language
dc.language.isoenlanguage
dc.publisherTaylor & Francislanguage
dc.rightsThis is an Accepted Manuscript of an article published by Taylor & Francis in The International Journal of Ventilation available online: http://www.tandfonline.com/10.1080/14733315.2016.11684094language
dc.subjectDemand-controlled ventilationlanguage
dc.subjectPassive houseslanguage
dc.subjectIndoor climatelanguage
dc.subjectSchoollanguage
dc.subjectQuestionnaireslanguage
dc.titleComparison of Two Ventilation Control Strategies in the First Passive House Standard Norwegian Schoollanguage
dc.typeJournal article
dc.typePeer reviewedlanguage
dc.typeJournal article
dc.date.updated2016-07-25T06:45:52Z
dc.description.versionacceptedVersionlanguage
dc.identifier.doihttp://doi.org/10.1080/14733315.2016.11684094
dc.identifier.cristin1359004


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel