Vis enkel innførsel

dc.contributor.authorSolevåg, Anne Lee
dc.contributor.authorCheung, Po-Yin
dc.contributor.authorLi, Elliott
dc.contributor.authorXue, Sarah Zhenchun
dc.contributor.authorO'Reilly, Megan
dc.contributor.authorFu, Bo
dc.contributor.authorZheng, Bin
dc.contributor.authorSchmölzer, Georg
dc.date.accessioned2019-07-23T11:37:29Z
dc.date.available2019-07-23T11:37:29Z
dc.date.issued2018-09-04
dc.identifier.citationSolevåg, A. L., Cheung, P. Y., Li, E., Xue, S. Z., O’Reilly, M., Fu, B., ... & Schmölzer, G. (2018). Chest Compression Quality in a Newborn Manikin: A Randomized Crossover Trial (August 2016). IEEE journal of translational engineering in health and medicine, 6, 1-5.en
dc.identifier.issn2168-2372
dc.identifier.urihttps://hdl.handle.net/10642/7336
dc.description.abstractThe objective of this paper was to examine the changes in applied force and rate of chest compression (CC) during 5 min of CC with a target CC rate of 90/min (CC90) or 120/min (CC120) with and without metronome guidance during simulated neonatal cardiopulmonary resuscitation (CPR). We performed a randomized controlled manikin trial. Fourteen neonatal resuscitation program providers performed CC90 and CC120 with or without a metronome in a randomized order. Peak and residual leaning force and CC rate each minute of CPR were analyzed with Friedman's analysis of variance (ANOVA) (within interventions) and two-way repeated measures ANOVA (between interventions). There was a large variability in force application, with no difference between groups. Peak and residual leaning forces in CC90 and CC120 did not change with time with or without a metronome. The CC rate increased with time in all groups except CC90 without a metronome. In conclusion, neither the target CC rate nor using a metronome influenced the peak and residual leaning forces during simulated neonatal CPR.en
dc.language.isoenen
dc.publisherIEEE Pressen
dc.relation.ispartofseriesIEEE journal of translational engineering in health and medicine;6
dc.rights(c) 20xx IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works. This is an open access article, originally published at https://doi.org/10.1109/JTEHM.2018.2863359en
dc.titleChest Compression Quality in a Newborn Manikin: A Randomized Crossover Trialen
dc.typeJournal articleen
dc.typePeer revieweden
dc.description.versionpublishedVersionen
dc.identifier.doihttps://doi.org/10.1109/JTEHM.2018.2863359
dc.identifier.cristin1671596


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel