dc.identifier.citationBremnes A, Kubosch, Ween B. Optimization of Codman® Hakim® adjustable valve radiography. Radiography Open. 2017;3(1)en
dc.identifier.issn2387-3345
dc.identifier.urihttps://hdl.handle.net/10642/5865
dc.description.abstractPurpose Cerebrospinal fluid shunt valves is an important tool in hydrocephalus treatment. Adjustable valves, sensitive to MRI, are onerous. They need be controlled; in case of re-settings. The vendor give advices for the radiographic procedure; however, hospitals use variations. The purpose was to investigate the different variations. Method Eight images consisting combinations of protocol features, were subjectively and anonymous rated for image quality. The panel consisted of 60 professionals; 50 radiographers and 10 radiologists, from two hospitals doing neurosurgery services. Signal-to-noise ratio compared the level of desired signal to the level of background noise. Results 348 scores were distributed onto all eight images, revealing the image quality difference was within acceptance. Options as valve on the head side near to the detector versus far to; differing geometry, use of head bowl versus not use, air-gap versus grids, were favored by both professional groups and at both hospitals in a clear priority image, given 2.5 times scores over average (108/43). Noise, revealed being the strongest indicator for priority of the best image for shunt evaluation. Conclusions It is a potential to improve image optimization in shunt radiography.en
dc.language.isoenen
dc.publisherOsloMet – storbyuniversiteteten
dc.rightsCopyright (c) 2017 Alexander Bremnes, Borgny Ween Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License.en
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectHydrocephalusen
dc.subjectOptimizationen
dc.subjectPositioningen
dc.subjectShunt radiographyen
dc.subjectStents and prosthesesen
dc.subjectVentriculo-atrial shunten
dc.titleOptimization of Codman® Hakim® adjustable valve radiographyen
dc.typeJournal articleen
dc.typePeer revieweden
dc.date.updated2018-01-29T11:53:35Z
dc.description.versionpublishedVersionen
dc.identifier.doihttp://doi.org/10.7577/radopen.1998
dc.identifier.cristin1464512
dc.source.journalRadiography Open


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Copyright (c) 2017 Alexander Bremnes, Borgny Ween

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
Med mindre annet er angitt, så er denne innførselen lisensiert som Copyright (c) 2017 Alexander Bremnes, Borgny Ween Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License.