Vis enkel innførsel

dc.contributor.authorWåde, Gunvor Gipling
dc.contributor.authorMoshina, Nataliia
dc.contributor.authorSebuødegård, Sofie
dc.contributor.authorHogg, Peter
dc.contributor.authorHofvind, Solveig
dc.date.accessioned2017-11-20T09:51:41Z
dc.date.accessioned2018-01-22T14:43:18Z
dc.date.available2017-11-20T09:51:41Z
dc.date.available2018-01-22T14:43:18Z
dc.date.issued2017
dc.identifier.citationWåde GG, Moshina N, Sebuødegård S, Hogg P, Hofvind SS. Compression forces used in the Norwegian Breast Cancer Screening Program. British Journal of Radiology. 2017;90(1071)en
dc.identifier.issn0007-1285
dc.identifier.issn1748-880X
dc.identifier.urihttps://hdl.handle.net/10642/5530
dc.description.abstractObjective: Compression is used in mammography to reduce breast thickness, which is claimed to improve image quality and reduce radiation dose. In the Norwegian Breast Cancer Screening Program (NBCSP), the recommended range of compression force for full-field digital mammography (FFDM) is 11–18 kg (108–177 N). This is the first study to investigate the compression force used in the programme. Methods: The study included information from 17,951 randomly selected females screened with FFDM at 14 breast centres in the NBCSP, during January–March 2014. We investigated the applied compression force on the left breast in craniocaudal and mediolateral oblique views for breast centres, mammography machines within the breast centres and for the radiographers. Results: The mean compression force for all mammograms in the study was 116 N and ranged from 91 N to 147 N between the breast centres. The variation in compression force was wider between the breast centres than that between mammography machines (range 137–155 N) and radiographers (95–143 N) within one breast centre. Approximately 59% of the mammograms in the study complied with the recommended range of compression force. Conclusion: A wide variation in applied compression force was observed between the breast centres in the NBCSP. This variation indicates a need for evidence-based recommendations for compression force aimed at optimizing the image quality and individualizing breast compression. Advances in knowledge: There was a wide variation in applied compression force between the breast centres in the NBCSP. The variation was wider between the breast centres than that between mammography machines and radiographers within one breast centre.en
dc.language.isoenen
dc.publisherBritish Institute of Radiology
dc.subjectCompressionen
dc.subjectMammographyen
dc.subjectBreast Canceren
dc.subjectRadiographeren
dc.titleCompression forces used in the Norwegian Breast Cancer Screening Programen
dc.typeJournal articleen
dc.typePeer revieweden
dc.date.updated2017-11-20T09:51:41Z
dc.description.versionpublishedVersionen
dc.identifier.doihttp://doi.org/10.1259/bjr.20160770
dc.identifier.cristin1433678
dc.source.journalBritish Journal of Radiology


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel