Vis enkel innførsel

dc.contributor.authorStarholm, Inger Marieen_US
dc.contributor.authorMirtaheri, Peymanen_US
dc.contributor.authorKapetanovic, Nihaden_US
dc.contributor.authorVersto, Tarjeien_US
dc.contributor.authorSkyttemyr, Gjermunden_US
dc.contributor.authorWestbye, Fredrik Tobiasen_US
dc.contributor.authorGjøvaag, Terjeen_US
dc.date.accessioned2016-03-09T10:39:37Z
dc.date.available2016-03-09T10:39:37Z
dc.date.issued2015en_US
dc.identifier.citationStarholm, I. M., Mirtaheri, P., Kapetanovic, N., Versto, T., Skyttemyr, G., Westby, F. T., & Gjovaag, T. (2015). Energy expenditure of transfemoral amputees during floor and treadmill walking with different speeds. Prosthetics and orthotics international, 0309364615588344.en_US
dc.identifier.issn0309-3646en_US
dc.identifier.otherFRIDAID 1202307en_US
dc.identifier.urihttps://hdl.handle.net/10642/3127
dc.description.abstractBackground: Walking energy expenditure, calculated as the percent utilization of the maximal aerobic capacity, is little investigated in transfemoral amputees. Objectives: Compare the energy expenditure of healthy participants (control participants) and transfemoral amputees walking with their respective preferred walking speeds on the treadmill (T PWS ) and floor (F PWS ). Study design: Randomized cross-over study. Methods: Oxygen uptake (VO 2 ) was measured when walking with the F PWS and T PWS . VO 2max was measured by an incremental treadmill test. Results: Mean ± standard deviation VO 2max of the transfemoral amputees and control participants were 30.6 ± 8.7 and 49.0 ± 14.4 mL kg −1 min −1 , respectively ( p < 0.05). T PWS for the transfemoral amputees and control participants was 0.89 ± 0.2 and 1.33 ± 0.3 m s −1 , respectively ( p < 0.01). F PWS for the transfemoral amputees and control participants was 1.22 ± 0.2 and 1.52 ± 0.1 m s −1 , respectively ( p < 0.01). Walking on floor with the F PWS , the energy expenditure of the transfemoral amputees and control participants was 54% and 31% of VO 2max , respectively ( p < 0.01). Walking on the treadmill with the T PWS , the energy expenditure of the transfemoral amputees and control participants was 42% and 29% of the VO 2max , respectively ( p < 0.05). Conclusion: Energy expenditure is higher for the transfemoral amputees than the control participants, regardless of walking surface. There are minimal differences in energy expenditure between treadmill and floor walking for the control participants but large differences for the transfemoral amputees. Clinical relevance During walking, the transfemoral amputees expend a larger percentage of their maximal aerobic capacity than healthy participants. With a low VO 2max , ordinary activities, such as walking, become physically more challenging for the transfemoral amputees than the control participants, and this may, in turn, have a negative effect on the walking range of the transfemoral amputees.en_US
dc.language.isoengen_US
dc.publisherSAGE Publicationen_US
dc.subjectGaiten_US
dc.subjectRehabilitationen_US
dc.titleEnergy expenditure of transfemoral amputees during floor and treadmill walking with different speedsen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.identifier.doihttp://dx.doi.org/10.1177/0309364615588344


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel