Vis enkel innførsel

dc.contributor.authorTennfjord, Merete Kolberg
dc.contributor.authorEngh, Marie Ellström
dc.contributor.authorBø, Kari
dc.date.accessioned2019-07-16T06:58:22Z
dc.date.available2019-07-16T06:58:22Z
dc.date.issued2017-03-16
dc.identifier.citationTennfjord, M. K., Engh, M. E., & Bø, K. (2017). An intra-and interrater reliability and agreement study of vaginal resting pressure, pelvic floor muscle strength, and muscular endurance using a manometer. International urogynecology journal, 28(10), 1507-1514.en
dc.identifier.issn0937-3462
dc.identifier.urihttps://hdl.handle.net/10642/7313
dc.description.abstractIntroduction and hypothesis Manometry is commonly used to assess pelvic floor muscle (PFM) function. Aims of the study were to assess intra- and interrater reliability and agreement of vaginal resting pressure, PFM strength, and muscular endurance using a high-precision pressure transducer. Methods A convenient sample of 23 women was included. The participants were tested twice by two examiners on day 1 and retested after 1 week by one examiner. Vaginal resting pressure, PFM strength, and muscular endurance were measured by manometer (Camtech AS). Intraclass correlation coefficient (ICC) and Bland–Altman plots were used to analyze reliability and agreement respectively. Results are presented with mean differences (bias) and minimal detectable change. Results Twenty participants completed the tests (mean age 55.8 years [27–71], mean parity 1.7 [range 0–3], and mean body mass index 23.7 [range 18.4–27.2, SD 2.4]). ICC values were very good (ICC >0.90) for all measurements. Considerable intervariation of scores, and outliers were seen for measurements representing the highest values. Agreement with mean differences (bias) and minimal detectable change for the intrarater assessment was for vaginal resting pressure: −2.44 ± 8.7 cmH2O, for PFM strength −0.22 ± 7.6 cmH2O, and for muscular endurance 0.75 ± 59.5 cmH2O/s. The interrater agreement for vaginal resting pressure was: 1.36 ± 9.0 cmH2O, for PFM strength 2.24 ± 9.0 cmH2O, and for muscular endurance 15.89 ± 69.7 cmH2O/s. Conclusions Manometry (Camtech AS) seems less accurate for the strongest women. In clinical practice, significant improvement in PFM variables needs to exceed the minimal detectable change to be above the error of measurement.en
dc.language.isoenen
dc.publisherSpringeren
dc.relation.ispartofseriesInternational Urogynecology Journal;28(10)
dc.rightsThis is a post-peer-review, pre-copyedit version of an article published in International Urogynecology Journal. The final authenticated version is available online at: http://dx.doi.org/10.1007/s00192-017-3290-yen
dc.subjectVDP::Medisinske Fag: 700en
dc.titleAn intra- and interrater reliability and agreement study of vaginal resting pressure, pelvic floor muscle strength, and muscular endurance using a manometeren
dc.typeJournal article
dc.typePeer reviewed
dc.description.versionacceptedVersionen
dc.identifier.doihttps://dx.doi.org/10.1007/s00192-017-3290-y
dc.identifier.cristin1460205


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel