Vis enkel innførsel

dc.contributor.authorStarholm, Inger Marie
dc.contributor.authorGjøvaag, Terje
dc.contributor.authorMengshoel, Anne Marit
dc.date.accessioned2011-02-07T12:29:43Z
dc.date.available2011-06-01T02:02:28Z
dc.date.issued2010-06
dc.identifier.citationStarholm, I.M., Gjøvaag, T. & Mengshoel, A.M. (2010). Prosthetics and Orthotics International, 34 (2), 184-194en_US
dc.identifier.issnPrint: 0309-3646
dc.identifier.issnOnline: 1746-1553
dc.identifier.urihttp://hdl.handle.net/10642/560
dc.description.abstractBackground and aim: Transfemoral amputees often report that walking on tilted pavements or in terrain with the prosthesis on the highest side is quite strenuous. This study investigates the energy expenditure of transfemoral amputees (n=8) walking on altered treadmill positions simulating different outdoor walking conditions. Method: Oxygen uptake at self selected speed of gait was measured during walking at three different treadmill positions: (I) Horizontal treadmill, (II) 3 % tilt in the sagittal plane and (III) 3 % tilt in both the sagittal and frontal plane of the treadmill. Results: The difference in oxygen uptake between position I and II was in median 4,3%, and 16,4% between position II and III (p≤ 0, 05 for all comparisons). The subjects utilized about 50% of their VO_2_max when walking in position I and II while energy expenditure increased to about 60% of the amputees VO_2_max when walking in position III. Conclusion: Transfemoral amputees use significantly more energy when walking on a moderately tilted surface in the frontal plane compared to walking with a tilt in the sagittal plane only. The prosthetic leg becomes functionally too long when the walking surface is tilted sideways, and the transfemoral amputees adopt a more energy consuming gait pattern.en_US
dc.language.isoengen_US
dc.publisherInforma Healthcareen_US
dc.relation.ispartofseriesProsthetics and Orthotics International;34 (2)
dc.subjectGaiten_US
dc.subjectWalking economyen_US
dc.subjectProsthesisen_US
dc.subjectWalking speeden_US
dc.subjectTransfemoral amputeesen_US
dc.subjectAmputeesen_US
dc.subjectVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750en_US
dc.subjectOxygen cost
dc.titleEnergy expenditure of transfemoral amputees walking on a horizontal and tilted treadmill simulating different outdoor walking conditionsen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionPostprint version. Original article can be found at URL: http://dx.doi.org/10.3109/03093640903585016en_US
dc.identifier.doihttp://dx.doi.org/10.3109/03093640903585016