Vis enkel innførsel

dc.contributor.authorEngelhart, Christina Hernandez
dc.contributor.authorVanbelle, Sophie
dc.contributor.authorØian, Pål
dc.contributor.authorPay, Aase Serine Devold
dc.contributor.authorKaasen, Anne
dc.contributor.authorBlix, Ellen
dc.date.accessioned2025-01-15T09:44:56Z
dc.date.available2025-01-15T09:44:56Z
dc.date.created2025-01-13T20:06:12Z
dc.date.issued2024
dc.identifier.issn0730-7659
dc.identifier.urihttps://hdl.handle.net/11250/3172750
dc.description.abstractBackground: We aimed to examine the inter-­ reliability and agreement among midwives when assessing the fetal heart rate (FHR) using the handheld Doppler. The primary aim was to measure the reliability and agreement of FHR baseline (baseline) as beats per minute (bpm). The secondary aims were to measure fluctuations from the baseline, defined as increases and decreases, and classifications (normal or abnormal) of FHR soundtracks. This is the first interrater reliability and agreement study on intermittent auscultation (IA) to our knowledge. Methods: The participant population consisted of 154 women in labor, from a mixed-­ risk population and admitted to hospital for intrapartum care. The rater population were 16 midwives from various maternity care settings in Norway. A total of 154 soundtracks were recorded with a handheld Doppler device, and the 16 raters assessed 1-­ min soundtracks once, through an online survey (Nettskjema). They assessed the baseline, FHR increase or decrease, and the FHR classification. The primary outcome, baseline, was measured with intraclass correlation coefficient (ICC). The secondary outcomes were measured with kappa and proportion of agreement. Results: The interrater reliability for the baseline (bpm) was ICC(A,1) 0.74 (95% CI 0.69–0.78). On average, an absolute difference of 7.9 bpm (95% CI 7.3–8.5 bpm) was observed between pairs of raters. Conclusion: Our results demonstrate an acceptable level of reliability and agreement in assessing the baseline using a handheld Doppler.en_US
dc.language.isoengen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleHow well can the fetal heart rate baseline be assessed by intrapartum intermittent auscultation? An interrater reliability and agreement studyen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1111/birt.12858
dc.identifier.cristin2291838
dc.source.journalBirthen_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal