Vis enkel innførsel

dc.contributor.authorChoidis, Petros
dc.contributor.authorTsikaloudaki, Katerina
dc.contributor.authorKraniotis, Dimitrios
dc.date.accessioned2020-09-16T21:25:11Z
dc.date.accessioned2021-01-22T08:01:45Z
dc.date.available2020-09-16T21:25:11Z
dc.date.available2021-01-22T08:01:45Z
dc.date.issued2020-06-30
dc.identifier.citationChoidis P, Tsikaloudaki, Kraniotis D. Hygrothermal performance of log walls in a building of 18th century and prediction of climate change impact on biological deterioration. E3S Web of Conferences. 2020;172en
dc.identifier.issn2267-1242
dc.identifier.issn2267-1242
dc.identifier.urihttps://hdl.handle.net/10642/9387
dc.description.abstractSeveral studies underline the dramatic changes that are expected to take place in nature and environment due to climate change. The latter is also expected to affect the built environment. Particular emphasis is currently given to the impact of climate change on historical structures. Within this context, it is important to use simple methods and novel tools in order to investigate pecific case studies. In this study, the climate change impact on the hygrothermal performance of the log walls in a historic timber building is presented. The building under investigation is the Fadum storehouse, also known as ‘the coated house’, located in Tønsberg, Norway. The storehouse dates to the late 18th century. It has a particular design with the main features of stumps or piles up to which it stands and the ‘coating’ that covers its outer walls. The main damage of the construction is related to the biological degradation of the wood. The hygrothermal performance of the log walls, as well as the exterior and interior climate, have been monitored and the results have been used to validate a Heat, Air and Moisture transport (HAM) model. The validated HAM model is then used to examine the performance of the log walls for both current and potential future climate conditions. The transient hygrothermal boundary conditions serve as the input parameters to a biohygrothermal model that is used to investigate the biological deterioration of the building components. The findings reveal that currently there is no mould risk for the main body of the construction, which is in accordance with the visual inspection. The passive systems of the building are highly conducive to these results, since they protect it from driving rain and other sources of moisture and eliminate the potential impact of future climate change risk scenarios.en
dc.description.sponsorshipThis work is a part of the HYPERION project. HYPERION has received funding from the European Union’s Framework Programme for Research and Innovation (Horizon 2020) under grant agreement No 821054.en
dc.language.isoenen
dc.publisherEDP Openen
dc.relation.ispartofseriesE3S Web of Conferences;Volume 172, 2020; 12th Nordic Symposium on Building Physics (NSB 2020)
dc.rightsCreative Commons Attribution 4.0 International (CC BY 4.0) Licenseen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectHygrothermal performancesen
dc.subjectLog wallsen
dc.subject18th century buildingsen
dc.subjectClimate changesen
dc.subjectWooden
dc.subjectBiological deteriorationen
dc.subjectMoistureen
dc.titleHygrothermal performance of log walls in a building of 18th century and prediction of climate change impact on biological deteriorationen
dc.typeJournal articleen
dc.typePeer revieweden
dc.date.updated2020-09-16T21:25:10Z
dc.description.versionpublishedVersionen
dc.identifier.cristin1830655
dc.source.journalE3S Web of Conferences
dc.relation.projectIDEC/H2020: 821054


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Creative Commons Attribution 4.0 International (CC BY 4.0) License
Med mindre annet er angitt, så er denne innførselen lisensiert som Creative Commons Attribution 4.0 International (CC BY 4.0) License