Vis enkel innførsel

dc.contributor.authorRabani, Mehran
dc.contributor.authorRabani, Mehrdad
dc.date.accessioned2020-01-10T11:48:57Z
dc.date.accessioned2020-01-22T13:58:28Z
dc.date.available2020-01-10T11:48:57Z
dc.date.available2020-01-22T13:58:28Z
dc.date.issued2019-05-31
dc.identifier.citationRabani M, Rabani M. Heating performance enhancement of a new design trombe wall using rectangular thermal fin arrays: An experimental approach. Journal of Energy Storage. 2019;24:1-15en
dc.identifier.issn2352-152X
dc.identifier.issn2352-152X
dc.identifier.urihttps://hdl.handle.net/10642/8000
dc.description.abstractIt has been nowadays recognized that addressing energy use in buildings can reduce the fossil fuels usage and CO2 emission. Trombe wall is a widely applicable passive solar design option that can significantly reduce the fossil fuel consumption in buildings. This paper experimentally dealt with the effect of applying vertical thermal fin on the absorber of Trombe wall with new design. Three types of aluminum, brass and copper fins were investigated. The experiments were carried out at arid climate of Yazd, Iran. The results showed that when the thermal fin is used the performance efficiency of the Trombe wall increases up to 3% in terms of stored energy within the Trombe wall and 6% in terms of natural convection heat transfer rate inside the channel. However, adopting more thermal fins on the absorber could not ensure higher heating efficiency in terms of stored energy for all cases. Furthermore, copper fin led to maximum heating efficiency and highest average room temperature among three fin types.en
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesJournal of Energy Storage;Volume 24, August 2019, 100796
dc.rights© 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ DOI: https://dx.doi.org/10.1016/j.est.2019.100796en
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectTrombe wallsen
dc.subjectThermal finen
dc.subjectStored energiesen
dc.titleHeating performance enhancement of a new design trombe wall using rectangular thermal fin arrays: An experimental approachen
dc.typeJournal articleen
dc.typePeer revieweden
dc.date.updated2020-01-10T11:48:57Z
dc.description.versionacceptedVersionen
dc.identifier.doihttps://dx.doi.org/10.1016/j.est.2019.100796
dc.identifier.cristin1709381
dc.source.journalJournal of Energy Storage


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

© 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
DOI: https://dx.doi.org/10.1016/j.est.2019.100796
Med mindre annet er angitt, så er denne innførselen lisensiert som © 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ DOI: https://dx.doi.org/10.1016/j.est.2019.100796