Vis enkel innførsel

dc.contributor.authorNordén, Kristine Røren
dc.contributor.authorDagfinrud, Hanne
dc.contributor.authorsemb, anne grete
dc.contributor.authorHisdal, Jonny
dc.contributor.authorMetsios, George S.
dc.contributor.authorSexton, Joseph
dc.contributor.authorFongen, Camilla
dc.contributor.authorBakke, Emilie Andrea
dc.contributor.authorTveter, Anne Therese
dc.date.accessioned2024-02-07T09:50:48Z
dc.date.available2024-02-07T09:50:48Z
dc.date.created2023-11-28T14:06:16Z
dc.date.issued2023
dc.identifier.issn2077-0383
dc.identifier.urihttps://hdl.handle.net/11250/3116110
dc.description.abstractCardiorespiratory fitness (CRF) is an excellent marker of overall health. This study aimed to assess criterion validity and responsiveness of estimated CRF models (eCRF) in patients with inflammatory joint disease (IJD). CRF was measured directly as peak oxygen uptake (VO2peak) by a Cardiopulmonary Exercise Test (CPET), while one generic eCRF model (eCRFGEN) and two disease-specific eCRF models (eCRFALT and eCRFPGA) were used to estimate CRF at baseline and after 3 months in 55 Norwegian patients with IJD. Moderate correlations were observed between eCRFGEN, eCRFALT, eCRFPGA, and VO2peak at baseline (ICC 0.60, 0.64 and 0.62, respectively) and 3 months (ICC 0.62, 0.65 and 0.57, respectively). All eCRF models overestimated measured VO2peak, and there was large variability in agreement of individual measurements at baseline and at 3 months. Weak correlations were observed for responsiveness of eCRFGEN (ICC 0.39), eCRFALT (ICC 0.40) and eCRFPGA (ICC 0.39). Mean differences between change in eCRF models and change in VO2peak were small, but the wide limits of agreement exceeded the pre-defined clinically acceptable margins. The eCRF models possessed adequate ability to detect ≥3.5 mL/kg/min improvement in VO2peak. eCRF may suffice for group-level assessment, but caution is advised when applying eCRF to individual patients with IJD.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleCriterion Validity and Responsiveness of Estimated Cardiorespiratory Fitness Models in Patients with Inflammatory Joint Diseaseen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.3390/jcm12216753
dc.identifier.cristin2204023
dc.source.journalJournal of Clinical Medicineen_US
dc.source.volume12en_US
dc.source.issue21en_US
dc.relation.projectNorges forskningsråd: 328657en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal