Vis enkel innførsel

dc.contributor.authorWåde, Gunvor Gipling
dc.contributor.authorSebuødegård, Sofie
dc.contributor.authorHogg, Peter
dc.contributor.authorHofvind, Solveig
dc.date.accessioned2018-12-21T07:34:43Z
dc.date.accessioned2019-02-11T13:21:08Z
dc.date.available2018-12-21T07:34:43Z
dc.date.available2019-02-11T13:21:08Z
dc.date.issued2018-07-13
dc.identifier.citationWåde GG, Sebuødegård S, Hogg P, Hofvind S. Breast compression across consecutive examinations among females participating in BreastScreen Norway. British Journal of Radiology. 2018;91(1090):1-9en
dc.identifier.issn0007-1285
dc.identifier.issn0007-1285
dc.identifier.issn1748-880X
dc.identifier.urihttps://hdl.handle.net/10642/6601
dc.description.abstractObjective: Breast compression is used in mammography to improve image quality and reduce radiation dose. However, optimal values for compression force are not known, and studies have found large variation in use of compression forces between breast centres and radiographers. We investigated breast compression parameters, including compression force, compression pressure and compressed breast thickness across four consecutive full field digital mammography screening examinations for 25,143 subsequently screened females aged 50-69 years. Methods: Information from females attending four consecutive screening examinations at two breast centres in BreastScreen Norway during January 2007 - March 2016 was available. We compared the changes in compression force, compression pressure and compressed breast thickness from the first to fourth consecutive screening examination, stratified by craniocaudal (CC) and mediolateral oblique (MLO) view. Results: Compression force, compression pressure and compressed breast thickness increased relatively by 18.3, 14.4 and 8.4% respectively, from first to fourth consecutive screening examination in CC view (p<0.001 for all). For MLO view, the values increased relatively by 12.3% for compression force, 9.9% for compression pressure and 6.9% for compressed breast thickness from first to fourth consecutive screening examination (p<0.001 for all). Conclusion: We observed increasing values of breast compression parameters across consecutive screening examinations. Further research should investigate the effect of this variation on image quality and females' experiences of discomfort and pain. Advances in knowledge: Breast compression force, compression pressure and compressed breast thickness increased across consecutive screening examinations, which might be of influence for the females' experiences of discomfort and pain during the examination and for image quality.en
dc.language.isoenen
dc.publisherBritish Institute of Radiologyen
dc.relation.ispartofseriesBritish Journal of Radiology;Volume 91, Issue 1090
dc.subjectBreast compressionsen
dc.subjectMammographyen
dc.subjectConsecutive examinationsen
dc.subjectFemale participationsen
dc.titleBreast compression across consecutive examinations among females participating in BreastScreen Norwayen
dc.typeJournal articleen
dc.typePeer revieweden
dc.date.updated2018-12-21T07:34:43Z
dc.description.versionpublishedVersionen
dc.identifier.doihttp://dx.doi.org/10.1259/bjr.20180209
dc.identifier.cristin1595528
dc.source.journalBritish Journal of Radiology


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel