Vis enkel innførsel

dc.contributor.authorHauge, Ingrid Helen Rysteen_US
dc.contributor.authorPedersen, Kristinen_US
dc.contributor.authorSanderud, Audunen_US
dc.contributor.authorHofvind, Solveigen_US
dc.contributor.authorOlerud, Hilde Mereteen_US
dc.date.accessioned2014-03-19T09:36:42Z
dc.date.available2014-03-19T09:36:42Z
dc.date.issued2011-02-17en_US
dc.identifier.citationHauge, I. H. R., Pedersen, K., Sanderud, A., Hofvind, S. & Olerud, H. M. (2011). Patient doses from screen-film and full-field digital mammography in a population-based screening programme. Radiation protection dosimetryen_US
dc.identifier.issn0144-8420en_US
dc.identifier.urihttps://hdl.handle.net/10642/1895
dc.description.abstractThe aim of this study was to compare mean glandular dose (MGD) in all full-field digital mammography (FFDM) and screen film mammography (SFM) systems used in a national mammography screening program. MGD from 31 screening units (7 FFDM and 24 SFM), based on an average of 50 women at each screening unit, representing 12 X-ray models (6 FFDM and 6 SFM) from five different manufacturers were calculated. The MGD was significantly lower for FFDM compared with SFM (craniocaudal): 1.19 versus 1.27 mGy, respectively, mediolateral oblique: 1.33 versus 1.45 mGy, respectively), but not all of the FFDM units provided lower doses than the SFM units. Comparing FFDMs, the photon counting scanning-slit technology provides significantly lower MGDs than direct and indirect conversion digital technology. The choice of target/filter combination influences the MGD, and has to be optimised with regard to breast thickness.en_US
dc.language.isoengen_US
dc.publisherOxford University Pressen_US
dc.relation.ispartofseriesRadiation protection dosimetry;en_US
dc.subjectMean glandular doseen_US
dc.subjectMammographiesen_US
dc.subjectScreeningen_US
dc.subjectPatientsen_US
dc.subjectRadiographicsen_US
dc.subjectRadiologyen_US
dc.subjectVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Radiologi og bildediagnostikk: 763en_US
dc.titlePatient doses from screen-film and full-field digital mammography in a population-based screening programmeen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionThis is a pre-copy-editing, author-produced PDF of an article accepted for publication in Radiation protection dosimetry following peer review. The definitive publisher-authenticated version Hauge, I. H. R., Pedersen, K., Sanderud, A., Hofvind, S. & Olerud, H. M. (2011). Patient doses from screen-film and full-field digital mammography in a population-based screening programme. Radiation protection dosimetry is available online at: http://dx.doi.org/10.1093/rpd/ncq598.
dc.identifier.doihttp://dx.doi.org/10.1093/rpd/ncq598


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel